FT8® MOBILEPAC®
-
Power generation within two days from arrival at the site
-
When soil-bearing capacity is excellent
No ground concrete work required
-
Integrated housing for the GT and generator
No site alignment required
-
Mutual operation at 50 Hz⇔60 Hz
Dual Frequency
FT8® MOBILEPAC®Gas Turbine Package
The FT8®MOBILEPAC® gas turbine package requires a small footprint utilizing an 80 by 54 foot area.
Very little advanced site preparation is required, and no foundation or concrete pad is necessary for installation of the unit. The unit is transportable by land, sea, or air and modularly packaged for quick, worldwide delivery and installation.
Features
- The standard package can easily be reconfigured to operate at either 50 Hz or 60 Hz.
- The trailer runs on public roads for prompt use as an emergency power source.
- The major components are packaged into two trailers to enable complete installation for power generation in only one day.
- Compact enough for air transport to minimize transport time (in addition to land and ocean transport).
- The advanced package design eliminates the need for concrete foundations, thereby reducing the cost and time required to complete installation.
Specifications
Output | 60 Hz/50 Hz:31 MW/29 MW(Dual Frequency) |
---|---|
Fuel | Dual Fuel (Gas/Oil) |
Starting Time | 5 minutes (cold start to full power) |
Type of Trailer | Mobile |
Trailer Installation | Flexible Trailer Siting |
Number of Trailers | 2 |
Cooling Method | Air Cooling |
Type of Generator/ Voltage of SWGR | Open-ventilated Air Cooling/ 15 kV |
NOx Control | Water Injection |
Starting Method | Hydraulic |
Type of Ignition | Electric Spark |
Turning | Unnecessary |
Reduction Gear | Unnecessary |
Configuration
50 Hz | 60 Hz | ||
---|---|---|---|
Compressor | Axial, multi-stage | ||
Combustor | Cannular | ||
Turbine | Axial, multi-stage | ||
Rotor | Build-up | ||
Output | Free | ||
Speed | rpm | 3,000 | 3,600 |
Gas Turbine | Dimension | 5m×2m×3m | |
Weight | 13t |
Performance
50 Hz | 60 Hz | ||
---|---|---|---|
ISO Base Rating | kW | 28,528 | 30,941 |
Efficiency | % | 34.7 | 36.7 |
LHV Heat Rate | kJ/kWh | 10,376 | 9,825 |
Btu/kWh | 9,834 | 9,312 | |
Exhaust Flow | kg/s | 92 | 92 |
Exhaust Temp. | ℃ | 496 | 491 |
F | 924 | 916 | |
Ramp Rate | MW/min | 15 | 15 |
Starting Time | Min | 5 (cold start to full power) | 5 (cold start to full power) |
Arrangements
Output | 60 Hz/50 Hz:31 MW/29 MW (Dual Frequency) |
---|---|
Fuel | Dual Fuel (Gas/Oil) |
Type of Trailers | Power and Control; in-line or parallel configuration |
Cooling Method | Air Cooling |
Solution
In addition to using the MOBILEPAC® unit (movable, dual-frequency power station) as an emergency power source for disasters and big events, we propose that customers make the most of the features of the MOBILEPAC® unit as a temporary power source for operation during the construction of large power plants of the type shown in the following images.
- 1. If surplus power is to be transmitted in addition to the power source for construction work, the MOBILEPAC® unit is very useful in countries with tight electricity supplies.
- 2.A trailer that runs on public roads enables easy disassembly and assembly on site. The MOBILEPAC® unit is moved easily to the next construction site once a power plant is completed. This portability cuts the cost of using a temporary power supply facility.
- 3. The portability also provides a power source during periodic inspections.
Delivery Record
Year of launch | 2004 |
---|---|
Number of units delivered | Over 130 Units |
Delivery Results
Products
- GTCC
- Steam Power
- IGCC
- Geothermal
-
Gas Turbines
- Product Lineup
- Comparative Performance
-
Technical Information
- Gas Turbines for Mechanical Drive Applications
- Cutting-Edge Elemental Technology Producing 1600°C Class J Gas Turbines
- Development of High-Efficiency Gas Turbine Applying 1600°C Class J Technology
- Combustor Technologies Supporting Stable Operation
- Overview and Verification Status of T-Point 2 Demonstration Facility
- Comprehensive Efforts from Development to Manufacturing
- Summary of Orders
- Development History
- Product Selection Assistant (Middle & small Class)
- Aero-derivative Gas Turbines
- Steam Turbines
- Boilers
- Air Quality Control Systems (AQCS)
- Generators
-
Control Systems
- What is DIASYS?
- DIASYS Netmation / DIASYS Netmation4S
-
DIASYS Optional Products
- IR-S Infrared Flame Detector
- Net IR-S Infrared Flame Detector
- Rail Mounting Net IR-S
- Boiler Tube Leak Detector
- Shaft Vibration Analyzer
- Simulator
- Advanced Combustion Pressure Fluctuation Monitoring System (A-CPFM) / Combustion Pressure Fluctuation Monitoring System (CPFM)
- Multi-Coal Fired Boiler Optimum Control
- DIASYS Solutions
- Fuel Cells
- Others
- Catalogue
- HIACS Series
- Technical Report